This website uses cookies
A cookie is a small text file that the website you are visiting temporarily stores on your computer. Cookies are used to ensure proper functionality and enhance user experience, however they also aid in tracking user behaviour on the internet. Please select "Proceed" if your are consenting to this.

Insotherm DPU

The polyurethane roof panels (Insotherm DPU) of Kamaridis GlobalWire Group are complex, self-supporting structural elements specially designed mainly for roof coatings of buildings. They can be used in numerous applications same as Insotherm RPU but their diversity makes them suitable for buildings housing animals, chemicals and general areas with overburdened atmospheric environment (usually acidic).

The DPU roof panels can be installed in structures with larger architectural requirements such as curved ceilings because their inner side is not from metal sheet but from different materials more flexible.


Characteristics
Loading Table
Seals - Support Materials - Special Items
Environment
Characteristics

Natural characteristics

The foam is odorless, prevents the formation of mold and fungus, remains chemically neutral and the humidity does not change its mechanical capacities. Sensitive to the texture of the excessive sunlight and in contact with water only at the exposed surface as well.



Σχέδιο Διατομής πάνελ πολυουρεθάνης Insotherm RPU

Λεπτομέρεια Σύνδεσης πάνελ πολυουρεθάνης Insotherm RPU

Foam expansion

Pentane is used in foam expansion which is friendly to the atmosphere and to the environment in general as it is chlorofluorocarbons free (CFC & HCFC Free.)

Technical Data

TECHNICAL DATA OF INSOTHERM DPU
Thickness
S
Thermal
Transmittance
K
Polyurethan
Density
Panel Weight
Steel Thickness 
0,5 + 0,5 mm
mm Kcal/m2h°C Wm2K kg/m3 kg/m2
30 0,48 0,56 40+-2 6,42
40 0,39 0,45 40+-2 6,84
50 0,32 0,37 40+-2 7,26
60 0,28 0,32 40+-2 7,68
80 0,22 0,25 40+-2 8,52

*All calculations are theoretical based on the specific weight of Steel 7.85

PANEL THICKNESS APPLICATIONS
APPLICATIONS


Thickness
(mm)

THERMAL TRANSMITTANCE(Κ)
(W/m2°C)
Decorative/Suspended ceilings    
Min. Requirement  30  
Sporting Facilities 40 0.53
Building Regulation Requirement 50 0.43
Industrial air-conditioned Facilities 60 0.36
Controlled Temperature Areas= °C 80 0.28
Refrigeration -10°C 100 0.23
Cooling Rooms -10°C 120 0.18
Cooling Rooms -20°C 140-160 0.16-0.15
Cooling Rooms -30°C 180 0.13
Cooling Rooms -45°C 200 0.11

 
Materials

Technical data of steel (EN 10327 / EN 10142 / EN 10143)

Quality DX51D or S-220 or S-250 or S-280 or S-320
Width 1.250mm / 1.070mm
Thickness 0.30mm – 0.70mm
Zinc 100-275 gr/m2
Tensile strength EN 10142

Technical paint data (SP)  

Topcoat 15-20 mic.
Primer 5 mic.
Backcoat 5-7 mic.

Specifications of PVC coating

In most storage and food processing facilities, the use of PVC covering panels is required. PVC is available in two colors (RAL9002 & RAL9010) and in 120mic thickness. Both colors are certified and suitable for use in food storage and processing applications according to all European standards and regulations (78/142 / CEE, 80/766 / CEE, 82/711 / CEE, 85/572 / CEE, 90 / 128 / CEE, 92/39 / CEE).

For special paints or coatings such as PVDF and HD, please contact us.

Flexible Coating:

Aluminum sheet, Kraft paper, paper aluminum, reinforced plasticized paper, tarpaper. Polyethylene paper, polyester

Polyurethane:

Density: 40+-2 Kg/m3 (ISO 845)
Thermal conductivity coefficient: λ=0,020 W/mK
or λ=0,018 Kcal/mhºC
at 10ºC (ASTM C 518)
Crushing strength at 10% compression: 0,22 N/mm2 (ISO 844)
Adhesion: 0,12 N/mm2 (ASTM D 162)
Closed cells percentage: 95-98% (ASTM D 285)
Fire resistance: Β2/Β3 class(DIN 4102)
Dimension stability: +-2 mm (ISO 2796)

Dimensions:

Width (effective): 1.000mm

Length (upon request): 2.000mm – 15.500mm

Thickness:  mm: 20 / 30 / 40 / 50 / 60 / 80 /100

Colours

Standard Colours

Note: The colors shown above may differ from those actually. The company is not responsible for any differences in shades due to display performance of each user.

Additional Features

On customer demand and upon consultation concerning the minimum production quantities and the delivery deadlines, the Insotherm DPU panels can be also manufactured with plates of different hardness, thickness and type, such as prepainted aluminum, copper, stainless steel as well as with different coatings depending on the particular requirements of the project..

Loading Table
Insotherm DPU PUR panels Loading Table
METAL SHEET THICKNESS    
SINGLE SPAN
purling spacing (m)
MULTIPLE SPAN
purling spacing (m)
1,50 1,75 2,00 2,25 2,50 2,75 1,50 1,75 2,00 2,25 2,50 2,75 3,00
t (mm) MAXIMUM UNIFORMLY DISTRIBUTED LOAD CAPACITY IN daN/m2
0,50 178 132 100 80 64   221 165 128 98 78 55  
0,60 214 159 119 94 76 49 266 198 153 118 99 66 51
0,75 270 196 150 116 92 63 322 249 191 186 123 83 65
1,00 392 274 200 157 127 78 402 324 255 196 165 110 82

*The measurements have a coefficient f < L/200 and breaking point measurements have a protection coefficient 2.5.
*1daN/m2 = 1,02 kp/m2

Seals - Support Materials - Special Items

For proper installation of roof panels (Insotherm DPU) a series of binders available from our company (self-screws, washers, metal caps, tires) is required. There are also special waterproofing materials for roofs with little inclination or structures exposed in very wet environment (butyl ate string, foam pads).

The use of 2.5 screws per m2 is recommended.

For screws with greater captive capacity please contact us.

Panel Thickness (mm)

Screw type

Captive capacity

30

5.5 x 120mm

8mm

40

5.5 x 120mm

8mm

50

5.5 x 130mm

8mm

60

5.5 x 150mm

8mm

80

6.3 x 150mm

8mm

100

6.3 x 170mm

8mm

 

After the installation of roof panels, it is necessary a number of special items for both sealing and aesthetic completion of the construction.

Each building has its own specific needs. Please contact our technical department in order to adapt the necessary special items on your own construction.

Environment

The DPU coating system of our company is produced from materials friendly to the environment, (CFC free), characterized as ecological and not considered to be harmful.

© 2024 | All Rights Reserved | Powered by PROTOCOL